PostPosted: Wed Mar 04, 15 12:05 pm    Post subject: Plastic pipe fittings Reply with quote
    

Looks like I'm going to have to use plastic pipe and plastic fittings for our hot and cold water. I'd rather use end feed copper but due to acidity have been recommended to avoid it.

So, anyone used the push-fit type plastic fittings? A bit of research suggests that if fitted properly they just as reliable as solder joints etc. Anyone have any particular recommendation for a brand to use or avoid? Any views on HEP20 or JG Speedfit?

Cost isn't a concern although it seems some brands have been discontinued which has caused problems, so a well known and sold brand would seem the way to go.

 
Nick



Joined: 02 Nov 2004
Posts: 34535
Location: Hereford
PostPosted: Wed Mar 04, 15 12:08 pm    Post subject: Reply with quote
    

Is this on mains pressure?

 
vegplot



Joined: 19 Apr 2007
Posts: 21301
Location: Bethesda, Gwynedd
PostPosted: Wed Mar 04, 15 12:25 pm    Post subject: Reply with quote
    

The push type fittings are good but you do need to make very clean scratch free connections to ensure their long term integrity. If you do use them it's advisable to be able to have good easy access wherever the joins are just in case of failure.

I wouldn't use plastic inside a house if the join is difficult to get at. A good copper fitting will give much longer problem free service than a plastic one assuming you don't have problems like you suggest e.g. acidic water.

 
sean
Downsizer Moderator


Joined: 28 Oct 2004
Posts: 42219
Location: North Devon
PostPosted: Wed Mar 04, 15 12:32 pm    Post subject: Reply with quote
    

We've got quite a few of them about the place and (touch wood) they've been fine. I'll ask our plumber which make he used.

 
Rob R



Joined: 28 Oct 2004
Posts: 31902
Location: York
PostPosted: Wed Mar 04, 15 12:45 pm    Post subject: Reply with quote
    

Only problem joints we've had in 5 years are metal fittings on plastic pipe, plastic joints have all been fine. Will look up the make in a bit.

 
Dee J



Joined: 22 May 2005
Posts: 342
Location: West Devon
PostPosted: Wed Mar 04, 15 12:47 pm    Post subject: Reply with quote
    

Mostly Speedfit here, odd bits of HEP and some copper... It all works. Plastic is very good for retro fit in old houses because it can be threaded through holes where rigid copper needs joists notched. Only real issue is the amount of thermal expansion in plastic pipes on hot services. It will move a lot. So don't clamp plastic too solidly and don't use plastic for exposed long runs where a nice neat straight pipe is needed. Temporary radiator install during refurbishment had about 20' of pipe clipped along a skirting. Straight when cold, but transformed into sid snake when hot!

 
dpack



Joined: 02 Jul 2005
Posts: 46244
Location: yes
PostPosted: Wed Mar 04, 15 1:02 pm    Post subject: Reply with quote
    

what they said

all i can add is what you gain on flexibility you lose on the extra clips etc to stop sagging etc

we have some in the central heating that i didnt fit but they seem ok on a pressurized system.

the few times i have had to use them clean and tidy pipe ends and tight but not too tight on the fittings if they are the turn sort seems to have worked fine

they are easier than copper end feed or compression but i still prefer copper which is probably an undeserved prejudice against plastic

 
perlogalism



Joined: 27 Nov 2009
Posts: 440
Location: Near Welshpool
PostPosted: Wed Mar 04, 15 1:23 pm    Post subject: Reply with quote
    

I've used a variety and found the Hep2O to be easiest to use and adjust. None of it has been in any longer than 6 years so ' can't really comment on longevity

 
Nick



Joined: 02 Nov 2004
Posts: 34535
Location: Hereford
PostPosted: Wed Mar 04, 15 1:25 pm    Post subject: Reply with quote
    

Conversely, mine are at least 15 years old, and trouble free, on hot and cold.

But, I cannot tell you the make. And they're pumped, not on mains pressure.

 
sean
Downsizer Moderator


Joined: 28 Oct 2004
Posts: 42219
Location: North Devon
PostPosted: Wed Mar 04, 15 1:34 pm    Post subject: Reply with quote
    

I've looked ours up. They're Speedfit. Up to eleven years old so far.

 
Rob R



Joined: 28 Oct 2004
Posts: 31902
Location: York
PostPosted: Wed Mar 04, 15 1:40 pm    Post subject: Reply with quote
    

Mostly speedfit here too, athough a couple of cheaper fittings here & there.

 
vegplot



Joined: 19 Apr 2007
Posts: 21301
Location: Bethesda, Gwynedd
PostPosted: Wed Mar 04, 15 1:41 pm    Post subject: Reply with quote
    

We have them mainly on the pumped hot water circuit and cold mains for the bathroom which is a relatively recent fit (in the last 5 years or so).

 
Cathryn



Joined: 16 Jul 2005
Posts: 19856
Location: Ceredigion
PostPosted: Wed Mar 04, 15 1:54 pm    Post subject: Reply with quote
    

We use both and thank goodness have replaced all our copper pipes they developed tiny pinholes everywhere.

We also use the bigger blue pipe for long runs of cold water. It works just as well and is cheaper.

If it's very acidic you might need a filter - a big tank filled with something similar to limestone that gets changed every two years here.

(Copper pipes, acidic water and highlighted hair = green hair.)

 
RichardW



Joined: 24 Aug 2006
Posts: 8443
Location: Llyn Peninsular North Wales
PostPosted: Wed Mar 04, 15 3:27 pm    Post subject: Reply with quote
    

Top tip,

Dont be tight buy the proper cutter.

I know you have a hack saw that could do the job for free but you then either get joints that leak or have to spend time trying to clean up the cut for a joint that will still leak.

The only time I have had problems is when I could not be bothered to go get the cutter & used the saw instead.

Oh & use the inserts if the brand you are using needs them.

Also use the dismantleable type (HEP2O used not to be, not sure if they are now).

 
dpack



Joined: 02 Jul 2005
Posts: 46244
Location: yes
PostPosted: Wed Mar 04, 15 4:18 pm    Post subject: Reply with quote
    

seconded on the proper pipe cutter ,it makes them easier to push into place as well as giving a dry job .

vertical runs of hot water between upstairs and loft or downstairs need plenty of clips as they seem to get extra baggy ,i think i did ours to 200mm centers cos the 800 that had been done looked very wobbly when things warmed up.if between joists the same applies but 350 centres seems ok

 